ProControl Series 2plus
Type C
Product Specification
The Type C ProControl is our entry-level model, but
don't let the low price fool you. It's a full-capability PLC and
SCADA system with all the benefits of our other ProControl models, including
stand-alone control, remote monitoring, on-board datalogging, and fax/pager
alarm reporting. With industrially-hardened inputs, instrument power
supplies, output relays, modem and keypad, the Type C contains everything
you need for the core of your control/telemetry system. It's ideal for
controlling pump stations, retrofitting to existing installations or when used
to replace that old alarm dialer. With our free ProViewTM
software, the Type C becomes a sophisticated operations manager, allowing you to
track flow rates and run times, receive alarm messages at your cell phone or
pager, and download data for reporting purposes. So why use just an
autodialer, when you can have a fully capable SCADA system for about the same
price?
| |
Model C1
$1,295 |
|
Inputs |
|
|
Discrete |
Ten (10) protected discrete inputs. Support for 2 flowmeters or
pulse accumulators with rates to 200Hz. |
|
Analog |
Two (2) 4-20ma inputs with built-in 24Vdc supply. Inputs are surge
and short-circuit protected. |
|
Outputs |
|
|
Discrete |
Eight (8) relay outputs rated at 1A, 120VAC |
|
Datalogging |
|
|
Discrete |
250 points. All logging occurs on
change of state. |
|
Analog |
500 points per channel. Flow
totals (25 per channel) |
|
Event |
500 points. |
|
Communications |
|
|
Modem |
ProView Software, PC to ProControl Interface - 9600 baud. |
|
FAX |
Alarm and Status Reports. Group 3, Class 2 FAX reporting at 9600 baud |
|
Pager |
TAP standard numeric and alpha-numeric paging at 300 to 2400 baud. |
|
Local |
Direct RS-232 Serial interface with automatic local/remote switching. |
|
e-mail |
Via third-party service, alarm and status reports |
|
User Interface |
|
|
Keypad |
1 x 4 membrane keypad |
|
LEDs |
LEDs: System Status, Communications Link, Auto Mode, Manual Mode |
|
Process Control |
|
|
System |
Up to 16 regular system processes total plus 8 startup and 8 shutdown processes. Processes run every 0.35
seconds. |
|
Alarms |
Generate shutdowns, two FAX reports and/or two Pager messages. |
|
Analog |
Four activation levels per analog input, On/Off control
and alarm reporting |
|
Power |
|
|
System |
10VAC, 30VA, external transformer provided |
|
I/O Supply |
24 VDC and 12VDC available for powering sensors/instruments. |
|
Environmental |
|
|
Dimensions |
11.5" long x 6" wide x 3.5" high. |
|
Weight |
4 lbs. |
|
Power Dissipation |
20W |
|
Operating Temp. |
-20C to +50C |
|
Humidity |
95% R.H. non-condensing |
|